top of page

Having this problem?

Voltage Auto Service specializes in advanced hybrid, plug-in hybrid and EV diagnostics. Schedule an appointment to have the fault properly tested before replacing parts.

2009 GMC Yukon Hybrid – No Start With P0BBD After Contaminated Fuel

  • Aug 15
  • 1 min read

CUSTOMER CONCERN

The engine will not start and the Service Hybrid System message is displayed after repeated restart attempts. Battery Energy Control Module DTC P0BBD is stored.

CAUSE

Inspection confirmed water-contaminated fuel had entered the fuel system, and repeated attempts to start the gasoline engine discharged the high-voltage battery.

CORRECTION

Remove the contaminated fuel, clean or replace the affected fuel-system components, perform the required engine-oil and induction services, and perform the hybrid-battery jump-assist procedure.