CUSTOMER CONCERN

The IMA warning is on with P0AE1, and replacing the junction-board/contactor unit did not correct the fault.

CAUSE

The Motor Power Inverter inside the Intelligent Inverter Unit remained faulty after the junction board and HV battery were ruled out.

CORRECTION

Remove and replace the Intelligent Inverter Unit/Motor Power Inverter, clear P0AE1, and verify IMA operation.